5 - 10 ---Selection of after 5 to 10 successive User Code trials, the keypad locks during 15 minutes.
The keypad can be reset to release the lock-out with the “Super User Code” in the following way.
Example : Release the lock-out --SUPER USER CODE # 9.
00 --- Disappearance of all the above lock-out securities.
USER PIN ENTRY MODE (Location 70)
LOCATION ENTRY MODES VALIDATION
70 1 or 2 #
USER PIN ENTRY MODES
Two modes 1 and 2 are available for User PIN entry options.
1 --- Auto Entry Mode
Auto Entry Mode requires no pressing of the # key following the User PIN for code checking.
In the Auto Entry Mode, the User PINs MUST be set in the same digit length of the Master Code (For example, if the Master Code is
5 digits, then all User PINs must be in 5 digits as well. All other User PINs not in 5 digits become invalid). When the number of digits
reaches, the system will check the User PIN automatically.
2 --- Manual Entry Mode – (Default)
Manual Entry Mode always requires the # key following of the User PIN for code checking. The User PINs can be 4 - 8 digits
arbitrary and they are NOT required to be in the same digit length of the Master Code.
PACIFIER TONES ON - OFF SELECTION (Location 71)
LOCATION FUNCTION MODES VALIDATION
71 1 or 0 #
PACIFIER TONES ON-OFF MODES
The Pacier Tone is the Beep Tones from the keypad, which include the tones of Successful Key entry (1 beep), the Output
Operation Announcer (2 beeps or 1 long beep) and the Unsuccessful User Code/Card entry (5 beeps).
NOTE :
The beeps for the Warning and the Power-up Delay do not belong to pacier tones and can not be set to OFF.
1 - -- Pacier Tone ON – (Default)
All the Pacier Tones available from the keypad are enabled. They are the response tones indicating the operation status of the
keypad after the User Code is entered.
0 - -- Pacier Tone OFF
All the Pacier Tones are OFF. Good for place needs for a silent environment.
OUTPUT OPERATION ANNOUNCER (Location 72)
LOCATION FUNCTION MODES VALIDATION
72 1 or 0 #
OUTPUT OPERATION ANNOUNCER
The announcer gives notication beep to the users and the visitors on the operation status of the outputs. There are two notication
modes available for the selection. The notication is also OFF while the Pacier Tone OFF mode in the Location 71 is selected.
1 --- 1 Second Long Notication -- (Default)
1 second notication beep is given when the output relay is activated with a valid Code or Egress Button. It is prepared to notify the
person outside the door when the lock is released and the door can be opened.