0 --- 2 Short Beeps Notication
2 short beeps notication is given when the output is activated with a valid Code.
STATUS LED FLASHING ON - OFF DURINGSTAND BY (Location 73)
LOCATION FUNCTION MODES VALIDATION
73 1 or 0 #
STANDBY FLASHING ON-OFF
Some people nd the ashing light of the status LED (the amber LED) is annoying during the keypad is on standby, especially at the
night time. The standby flashing can be ON-OFF with the setting here.
1 --- Standby Flashing ON -- (Default)
The Status LED gives Standby Flashing all the time during the keypad is on standby. It also gives all the light indications showing
the operation status of the system.
0 --- Standby Flashing OFF
The Standby Flashing is disabled but it does not affect the system status indications. All the light indications from it are unchanged.
DOOR FORCED OPEN WARNING & TIMING (Locat ion 80)
LOCATION FUNCTION MODES VALIDATION
80 0 or 1 - 999 #
DOOR FORCED OPEN WARNING ON-OFF & TIMING
The Door Forced Open Warning function requires a Door Position Sensing switch (usually a magnetic contact) to work with. Once
a Timing Figure is put into the Function Mode box, the warning mode is enabled.
0 --- Door Forced Open Warning OFF – (Default)
1 - 999 --- Door Forced Open Warning & Alarm ON & Timing
The Timing Figure for the Warning can be 1-999 seconds. The keypad generates the door forced open warning beeps and
activates the alarm output (Terminal 13) instantly if the door is forced to open without a valid User PIN or pressing of the Egress
Button. The beeps and alarm will last as long as the time set on the timer and it can be stopped at anytime with an User PIN in
Group 1 before the end of the time.
The Manner of The Door Forced Open Warning:
a) The door is forced to open (without using PIN or Egress Button) – Warning & Alarm
b) The door is opened with PIN – No Warning or Alarm
c) The door is opened with Egress Button – No Warning or Alarm
DOOR PROPPED - UP WARNING & THE DELAY TIME (Location 81)
LOCATION FUNCTION MODES VALIDATION
81 0 or 1 - 999 #
DOOR PROPPED-UP WARNING ON-OFF & TIMING
If somebody opened the door and it is left open longer than the allowable delay time, the keypad will generate door propped-up
warning until the door is re-closed. There is warning beeps from the keypad only but does not activates the alarm output.
0 --- Door Propped-up Warning OFF – (Default)
1 - 999 --- Door Propped-up Warning ON & The Delay Time
The Delay Time can be 1 to 999 seconds. It is the time allows the door to open without starting of the warning.