KEYPAD PROGRAMMING MAKE SIMPLE – FOR GENERAL USERS
This is a multi purpose keypad. It has many functions for user’s selection. For those general users taking the keypad for door strike
only, most of the features can be kept in their Default values. Only the User PINs and a private Master Code are necessary to
program for the system.
PROGRAMMING
NOTE:
a) The * button is equivalent to the button in the keypad with bell button.
b) Wait 1 minute until the end of the power up delay.
1) Set System into Programming Mode with The Factory Set Master Code 0000
0000 ** --- - 2 beeps, system is inP rogramming Mode.
NOTE: If the Master Code is forgotten, use the DAP Code to set the system into programming mode. See DAP CODE 8080 on the
previous page for the details.
2) Change The Factory Set Master Code to Owner’s Private Master Code for Security Reason
01 32 89 # ---- 2 beeps, 3 2 8 9 is a Master Code for example here only 3289 is the new Master Code and the 0000 is
erased
3) Set an “User PIN” to Operate The Output 1 for Door Open
10 2 001 8321 #
(a ) (b) (c) (d) (e)
(a) 10 = Programming Location for Output 1
(b) 2 = Programming for User PIN
(c) 001 = One of the 1,000 User IDs for the User PIN from 000-999
(d) 8321 = The User PIN that is programmed for door open. 8321 is an User PIN for example here only
(e) # = Conrm the User PIN, 2 beeps
REMARK:
If more User PINs are required for Output 1, repeat the procedures (3) above with other User IDs, such as 002, 003, 004 --- 999 etc.
Total 1000 users are allowed. See Programming Location 10 for the details.
4) Close The Programming Mode
** ---- 2 beeps
The programming mode is closed. The keypad is back to normal operation mode.
OPERATION
5) Open The Door with The User PIN
8321 # ---- 2 beeps, the door is open
REMARK:
In the next Section, “KEY IN AND STORE THE DESIRED VALUES” describes all the features and functions of the system in detail.
Users can follow them to tailor the desired values for their access control system. Suggest the general users also spend some time
on them to get acquaint with this powerful system for future expansion.
36 Rev. 01 - 05/201167411245