PUSH
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
INTELLIGENT EGRESS BUTTON – AN UNIQUE FEATURE OF A CONTEMPORARY KEYPAD
Most of the keypads for access control are just for controlling of “Going In” from outside. It is not enough for today’s access control
systems. In fact, controlling of “Going Out” is also very important in many public passage areas. They are not allowed to use locks
or digital keypads for stopping of “Going Out” due to safety reasons. Such as hospitals, kindergartens, elderly homes, convenient
stores, emergency exits etc.. The wardens, teachers, shopkeepers and the guards are always required to keep an eye on people
to prevent unattended leaving, shoplifting, and illegal use of the emergency exits.
The Intelligent Egress Button can be programmed to do something to get the attention of the person on duty before the door is
opened. The button offers programmable egress delay, delay with warning, holding button required for the delay, momentary
button contact with warning for the delay and even gives alarm when a controlled door is opened.
Locations 90 and 91 below are the places for setting the desired functions for the Egress Button.
The functions programmed to the Egress Button do not affect the normal operation of the system with its keypad. For the safety
consideration, the operation of the keypad with PIN or Code is always in the first priority to give instant action to the output relay 1
for door strike.
It is NOT required to program the Egress Button with the special function in normal use. Just leave it on its default Values.
EGRESS DELAY, WARNING AND AL ARM (Location 90)
LOCATION FUNCTION MODES DELAY TIME VALIDATION
90 1 - 6 0 or 1 - 99 #
CONFIGURATIONS OF THE EGRESS WARNING AND ALARM
Key in the number to enable 1 of the 6 congurations described below:
1 --- Momentary Contact Mode without Warning -- (Default)
• Press the Button once. No warning or alarm is given during Egress Delay.
• Good for silent area. The people have to wait for the door open until the delay time reaches.
2 --- Momentary Contact Mode with Warning Beep
• Press the Button once. The system gives Warning Beeps during the Egress Delay.
• Good for the place required attention. The keypad beeps during the people are waiting for the door open.
3 --- Momentary Contact Mode with Warning Beep & Alarm
• Press the Button once. The system gives Warning Beeps and also activates its Alarm O/P during the
Egress Delay
• Good for door for the authorized people only. The keypad beeps and report alarm to a security
system during the people are waiting for the door open.
• This is usually an “Emergency Exit”. The door can be opened with the Keypad without triggering of the
Buzzer and Alarm Output.
4 --- Holding Contact Mode without Warning
• Press and hold the Button. No warning or alarm is given during the Egress Delay.
• Good for the silent area. The people require to press & hold the button until the delay time reaches for
the door open.
5 --- Holding Contact Mode with Warning Beep
• Press and hold the Button. The system gives Warning Beeps during Egress Delay.
• Good for the place required attention. The keypad beeps while the button is kept pressed during the
people are waiting for the door open.
6 --- Holding Contact Mode with Warning Beep & Alarm
• Press and hold the Button. The system gives Warning Beeps and also activates its Alarm O/P during
Egress Delay.
• This is usually an “Emergency Exit”. The door can be opened with the Keypad without triggering of the
Warning and Alarm.
EGRESS DELAY TIMER
0 - -- No Delay – (Default)
46 Rev. 01 - 05/201167411245