Personal Safety &
Lock-out
ENTRY MODE:
1---Auto Mode
2---Manual Mode
LOCK-OUT CODE:
1---10 Trial, Lock-out 60 Sec.
2---10 Trial, Activates Duress
5-10---5-10 Trial, Lock-Out
15
Minutes
00---No Lock-out
60
60 LOCK-OUT CODE #
Code = 1,
10 Trials,
Lock-out 60
Seconds
70
PIN Entry Mode
70 ENTRY MODE #
Mode = 2,
Manual Mode
FUNCTION MODE / TIME:
0---OFF
1-999 Seconds
FUNCTION MODE:
0---OFF
1---ON
71
72
73
Output Announcer
Pacier Tone ON-OFF
Standby LED Flashing
72 FUNCTION MODE
71 FUNCTION MODE #
73 FUNCTION MODE #
Mode = 1
Announcer ON
Mode = 1,Pacier
Tone ON
Mode = 1,
Flashing On
Door Forced Open
Warning & Time
80
Propped-up Warning &
Time
81
80 FUNCTION / TIME #
Mode = 0,
Door Forced
Open Warning OFF
81 FUNCTION / TIME #
Mode = 0,
Propped-up
Warning OFF
CODE 1 - FUNCTION
MODE:
1---Momentary, No warning
2---Momentary, with warning
3---Momentary, with warning
+ Alarm
4---Hold Contact, No
warning
5---Hold Contact, with
warning
6---Hold Contact, with
warning + Alarm
CODE 2 - DELAY TIME:
0---No Delay
1-99 Seconds
Egress Delay Warning
&
Alarm
90
90 CODE 1 CODE 2 #
Mode = 1
Momentary,
No warning
TIME = 0
No Delay
ALARM TIME:
0---No Alarm
1-999 Seconds
91
Door Opening Alarm
& TIMER
91 ALARM TIME #
Time = 0,
No Alarm
Factory Set Master Code
for User to set system in
programming Mode at the
first time.
THIS IS NOT A PERMANENT
SYSTEM CODE & IT IS
CHANGED IF A NEW
MASTER
CODE IS PROGRAMMED.
0000 **
OR
NEW MASTER CODE **
0000
System in Programming Mode
SYSTEM
CODES
FUNCTION CODE ENTRY RESULTS
REFRESH CODE -- Refresh
the system and set all its
function back to default
Values.
9999 #
9999
All programmed data are cleared and
back to the default values except the
Master Code
PUSH
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
49Rev. 01 - 05/201167411245