Liberty 100 Smart Electricity Meter Technical Reference Manual
Diagnostic Displays in Credit Mode
(timeout 4 secs)
Press key 4 to return to the 1
st
display.
Press key B to scroll back up the display list.
Press key A to resume the auto-cycle display.
Table 33: Key '4' Diagnostic display in Credit mode
Key 5: Load limit threshold
Title 1: Load limit threshold
(timeout 2 secs)
Followed by value
Or
(timeout 4 secs)
Press key A to resume the auto-cycle display.
The display associated with key 5 indicates the
current load limit kW threshold. If load limit feature is
disabled then it will display ‘----------‘.
Table 34: Key '5' Diagnostic display in Credit mode
Key 6: Power On/Off hours and counter
Title 1: Power On/Off hours
(timeout 2 secs)
Followed by value
(timeout 4 secs)
Press key 6 to advance to the next display
The 1
st
set of displays associated with key 6
indicating the number of hours the electricity meter
has been without mains power i.e. running on
battery.
The example shows that the meter has been on
power for 371 hours.
Title 2: Power up counter
The 2
nd
set displays the number of times the meter
has been powered up.