Liberty 100 Smart Electricity Meter Technical Reference Manual
EMC/Electric Surge BS EN 50470-1, 50470-3
Compliance
Metrology Active Energy - BS EN 50470-1, 50470-3 Class B
Reactive Energy - IEC 62053-21, Class 1.0
Meter mounting, size and
BS 7856
Power source
RTC backup source
Battery life (typical)
Minimum shelf-life (typical)
Mains supply
Lithium battery
20 years
2 years
Data retention
Display format
Image area
Life expectancy
Alphanumeric with icons
80 x 24
20 years
Environmental
Operating temperature
Storage temperature
Operating humidity
- 25 °C to + 55 °C
- 25 °C to + 70 °C
Up to 95% non-condensing
4.2 Handling, Storage and Operating Conditions
Liberty 100 meter is an electronic device containing delicate components, and should be handled carefully
during transit, storage and installation. The meter should be protected from physical vibration and shocks.
Wherever possible the meter should be kept in its original packaging until it is installed at the customer’s site.
Temperature and humidity must be maintained within the limits expressed in the above table.
Proper installation and removal procedures should be followed, in order to prevent damage or injury. Physical
damage to the meter’s case could indicate damage to internal components. Under no circumstances should an
attempt be made to install a damaged meter.
Ideally the meter should be stored and operated in a dry, well ventilated, climate-controlled building. Rapid
changes in temperature and humidity should be avoided.