4 Meter Specifications
4.1 General Specification
Specification Description
Mechanical
Front cover Transparent fire-retardant polycarbonate material - V0
Opaque polycarbonate material
Meter base with terminal block Opaque 10% glass filled fire-retardant polycarbonate
Terminals Brass material; tunnel type each with minimum internal
Opaque fire-retardant polycarbonate material - V0 grade
Sealing provisions 2 seals on the front cover, 2 seals on the hub cover and 1
seal on the terminal block cover
Display LCD with backlight, 10 starburst character (7mm high) with
icons. Display visibility angles:
Vertical: 30 degrees up and 35 degrees down from normal
(straight on)
Horizontal: 30 degrees left and right from normal
Display operating temperature range from -20
0
0
Electrical
Voltage measuring element
Current measuring element
Rated current 0.5-10(100) A
The meter can withstand 460 V supply voltage and 120 A
current for 48 hours with no degradation in metrology.
Burden
Current circuit
< 0.1 VA
< 2 W ,< 4 VA average (with Skyline-i 510 fitted)
Metrology LED Red LED, 3200 pulses/kWh
Contactor Integral, 100A, UC3 (IEC 62055-31)