EasyManua.ls Logo

Secure Liberty 100 - Table 30: Key 1 Diagnostic Display in Credit Mode

Secure Liberty 100
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 96 of 116
Liberty 100 Smart Electricity Meter Technical Reference Manual
BGX501-767-R02
Diagnostic Displays in Credit Mode
Press key 1 to advance to the next display
Title 2: Software version
(timeout 2 secs)
Followed by
(timeout 4 secs)
Press key 1 to return to the 1
st
display.
Press key B to scroll back up the display list.
Press key A to resume the auto-cycle display.
The 2
nd
set of displays identifies the metrology
firmware and version.
The example shows that B200 is the metrology
firmware in which ‘00’ is the version number.
Table 30: Key '1' Diagnostic display in Credit mode
Key 2: Switch Off reason and switch On/Off counter
Title 1: Switch On/Off reason code
(timeout 2 secs)
Followed by value
Or
Or
Or
Or
Or
The 1
st
set of displays associated with key 2 display
the reason code for the switch being open.
There are 7 different switch open reason codes, the
reason associated with each code are given below:
00: switch close.
01: supply disconnected manually.
04: supply off due to overload.
08: supply off due to an event.
10: supply disconnected via supply UTRN.

Table of Contents

Other manuals for Secure Liberty 100