Liberty 100 Smart Electricity Meter Technical Reference Manual
Diagnostic Displays in Prepayment Mode
Title 2: Software version
(timeout 2 secs)
Followed by value
(timeout 4 secs)
Press key 1 to return to the 1
st
display.
Press key B to scroll back up the display list.
Press key A to resume the auto-cycle display.
The 2
nd
set of displays identifies the metrology
firmware and version.
The example shows that B2–00 is the metrology
firmware in which ‘00’ is the version number.
Table 36: Key '1' Diagnostic display in Prepayment mode
Key 2: Switch Off reason and switch On/Off counter
Title 1: Switch On/Off reason code
(timeout 2 secs)
Followed by value
Or
Or
Or
Or
Or
Or
The 1
st
set of displays associated with key 2 reveals
the reason for the switch being open.
There are in total 15 different switch off reason
codes, the reason associated with each code are
given below:
00: switch closed.
01: supply is disconnected manually.
02: supply off due to no credit in the account.
04: supply off due to overload.
08: supply off due to an event.
10: supply disconnected via supply UTRN.