58
CONTROL UNIT
11
After the volume has been replaced, be sure to set the volume value on the test
mode calibration screen and the input test screen and check variations in the
volume value
After adjusting or replacing a microswitch, always check ON/OFF of the switch
on the input test screen of the test mode
Handle parts inside the Control Unit very carefully. Be especially careful to avoid
damage, deformation or loss of these parts. If any one of these parts is lost or
defective, it can result in damages and/or faulty operations
When working with the product, be sure to turn the power off. Working with the
power on may cause an electric shock or short circuit
Be careful not to damage the wires. Damaged wires may cause an electric
shock, short circuit or present a risk of re
Do not touch any parts that are not specied in these directions. Touching
unspecied locations may lead to electric shock or cause short circuits
This work should be performed by Site Maintenance Personnel or other skilled
professionals. Work performed by non-technical personnel can cause a severe
accident such as an electric shock
Exercise due caution in performing soldering procedures. If soldering iron is
handled carelessly, there could be res or burns
Proceed very carefully when heating thermal contraction tube. Careless
operations can result in res or burns
When fastening plastic parts, be careful not to tighten screws and nuts
excessively. Otherwise parts may be damaged, resulting in injuries from
fragments, etc
Be careful not to get hand or nger caught when removing or attaching the parts
Disconnection and connection of connectors will be performed within the
narrow cabinet space. Take due care not to scratch or otherwise injure yourself
Take care when carrying the removed Control Units. Such heavy lifting carries a
risk of injury to back or shoulders
If the operability of the Control Unit is unsatisfactory, or if settings on the test mode calibration screen
are ine󰀨ective, the problem could be a defective mechanism, displacement of the position where
volume or microswitch has been fastened, or malfunctioning of volume or microswitch.
Carry out the following procedure to replace Control Unit or microswitch. Also be sure to grease the
mechanical components of the Control Unit once every 3 months.