3-4
2) Digital MultiMeter Function
DC V
Scope V/Div DMM Range Resolution Accuracy Impedance
0.5, 1, 2 5V 0.001V
±(0.3%+3)
1 MΩ
5, 10, 20 50V 0.01V
50, 100, 200 500V 0.1V
±(0.5%+5)
500 1000V 0.1V
AC V
Scope V/Div
DMM
Range
Resol.
Accuracy (Hz)
Imped.
50~450 0.45k~5k 5k~20k
0.5, 1, 2 3V 0.001V
±(0.75%
+5)
±(2%+5)
±(3.5%
+5)
1 MΩ
5, 10, 20 30V 0.01V
50, 100, 200 300V 0.1V
500 750V 0.1V N/A
The Voltage for more than 200V in Frequency range 5kHz to 20kHz: Not Specification
OHM
Scope
Div
DMM Range
Resolution Accuracy Over Load Protection
1 kΩ 5 kΩ 0.001 kΩ
±(0.5%+5)
600V DC or
AC rms
10 kΩ 50 kΩ 0.01 kΩ
100 kΩ 500 kΩ 0.1 kΩ
1 MΩ 5 MΩ 0.001 MΩ
±(0.75%+10)
Continuity Buzzer
Test Voltage Threshold Over Load Protection
1.7V 100 digits 600V DC or AC rms
RPM
Function Range Resolution Accuracy
RPM 120 - 12,000 1RPM ± 2RPM
% Duty 1% - 98%
Dwell 3.6° - 352.8°
Pulse Width 2 uS - 450 mS (Pulse Width > 2 uS)
Frequency 2Hz - 1MHz