EasyManua.ls Logo

Seintek S2800 - Page 23

Seintek S2800
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-4
2) Digital MultiMeter Function
DC V
Scope V/Div DMM Range Resolution Accuracy Impedance
0.5, 1, 2 5V 0.001V
±(0.3%+3)
1 MΩ
5, 10, 20 50V 0.01V
50, 100, 200 500V 0.1V
±(0.5%+5)
500 1000V 0.1V
AC V
Scope V/Div
DMM
Range
Resol.
Accuracy (Hz)
Imped.
50~450 0.45k~5k 5k~20k
0.5, 1, 2 3V 0.001V
±(0.75%
+5)
±(2%+5)
±(3.5%
+5)
1 MΩ
5, 10, 20 30V 0.01V
50, 100, 200 300V 0.1V
500 750V 0.1V N/A
The Voltage for more than 200V in Frequency range 5kHz to 20kHz: Not Specification
OHM
Scope
Div
DMM Range
Resolution Accuracy Over Load Protection
1 kΩ 5 kΩ 0.001 kΩ
±(0.5%+5)
600V DC or
AC rms
10 kΩ 50 kΩ 0.01 kΩ
100 kΩ 500 kΩ 0.1 kΩ
1 MΩ 5 MΩ 0.001 MΩ
±(0.75%+10)
Continuity Buzzer
Test Voltage Threshold Over Load Protection
1.7V 100 digits 600V DC or AC rms
RPM
Function Range Resolution Accuracy
RPM 120 - 12,000 1RPM ± 2RPM
% Duty 1% - 98%
Dwell 3.6° - 352.8°
Pulse Width 2 uS - 450 mS (Pulse Width > 2 uS)
Frequency 2Hz - 1MHz