10-6
10.1.9. CKP LoRes
Measures and compares the Crankshaft low accuracy sensor signal.
Path:
Î
Î
Î
CKP LoRes
CKP LoRes
BLACK TO SENSOR BODY OR
ENGINE (CHASSIS)
RED TO SENSOR OUTPUT
To engine (chassis)
To sensor output
Measured waveform should be
stable.
Normal CKP LoRes Sensor waveform
10.1.10. CKP HiRes
Measures and compares the Crankshaft high accuracy sensor signal.
Path:
Î
Î
Î
CKP HiRes
CKP HiRes
BLACK TO SENSOR BODY OR
ENGINE (CHASSIS)
RED TO SENSOR OUTPUT
To engine (chassis)
To sensor output
Measured waveform should be
stable.
Normal CKP HiRes Sensor waveform