| Digital interface | RS485 |
|---|---|
| Housing | Stainless steel |
| Protection class | IP65 |
| Resolution | 0.1 °C |
| Response time | 1 ms |
| Emissivity setting | 0.100 to 1.000 |
| Analog output | 0/4 to 20 mA, 0 to 10 V |
| Power supply | 24 V DC |
| Storage temperature | -20 to 70 °C |
| Battery Life | Not applicable |
| Spectral range | 8 - 14 µm |
Ensures personnel operating the device have read and understood the manual before use.
General safety guidelines for connecting the device to mains voltage to prevent injury.
Safety precautions for using the laser targeting light, including eye safety and beam direction.
Safety advice for using the view finder with high temperatures to protect eyes from glare.
Defines operator responsibilities for workplace safety and system integration compliance.
Details 14-wire cable colors, pin assignments, and notes for older 12-wire cables.
Lists default settings for pyrometer parameters like response time and interface type.
Explains power connection requirements (24V DC) and operating status LEDs.
Describes configuration of analog outputs for temperature or control signals.
Details setup for digital inputs/outputs and their assigned functions.
Explains serial communication setup for PC connection and bus operation.
Covers pyrometer mounting options using rails, threaded holes, and vibration reduction.
Guidance on installing optical fibers and optics, including bending radius and handling.
Explains proper assignment of fiber to pyrometer/optics and correct mounting steps.
Details steps for connecting the optics, including tightening the lock nut correctly.
Explains how to align the pyrometer properly for accurate temperature measurement.
Describes using the laser targeting light for alignment and associated safety precautions.
Explains alignment using the view finder and provides eye protection advice.
Covers adjusting the focal distance for optimal spot size measurement.
Instructions for manually adjusting focus using release and lock rings.
Describes setting distance using device buttons or PC software for motorized focus.
Details manual focusing procedures for fiber optic lenses OL25 and OL12.
Explains the function of the PAR, Enter, Arrow keys, and Key Lock for device operation.
Lists adjustable pyrometer parameters and their available settings for configuration.
Explains response time adjustment for tracking temperature changes accurately.
Instructions for installing and connecting the pyrometer to the SensorTools software.
Software for updating the pyrometer's firmware via a USB connection.