MX-5001N SIMULATION 6 – 53
* Item L: 1 Count = 1s Change
Correction value for the other items: 1 count for 1°C change
* Item D, F: When B5 size, correction of "-5" is made for item D and item F.
* Item G, I: When B5 size, correction of "-5" is made for item G and item I.
M HL_UM HEAVY LL Correction value for heavy paper TH_UM set value under
LL environment
1 - 99 55 55 55
N HL_LM HEAVY LL Correction value for heavy paper TH_LM set value under
LL environment
1 - 99 55 55 55
O HL_E HEAVY LL Correction value for heavy paper TH_E set value under LL
environment
1 - 99 50 50 50
P HL_UM OHP LL Correction value for OHP TH_UM set value under LL
environment
1 - 99 55 55 55
Q HL_LM OHP LL Correction value for OHP TH_LM set value under LL
environment
1 - 99 55 55 55
R HL_E OHP LL Correction value for OHP TH_E set value under LL
environment
1 - 99 50 50 50
S HL_UM ENVELOPE LL Correction value for envelope TH_UM set value under LL
environment
1 - 99 55 55 55
T HL_LM ENVELOPE LL Correction value for envelope TH_LM set value under LL
environment
1 - 99 55 55 55
U HL_E ENVELOPE LL Correction value for envelope TH_E set value under LL
environment
1 - 99 50 50 50
V HL_UM GLOSS LL Correction value for glossy paper TH_UM set value under
LL environment
1 - 99 55 55 55
W HL_LM GLOSS LL Correction value for glossy paper TH_LM set value under
LL environment
1 - 99 55 55 55
X HL_E GLOSS LL Correction value for glossy paper TH_E set value under LL
environment
1 - 99 50 50 50
Y HL_UM E-STAR LL Correction value for preheating TH_UM set value under LL
environment
1 - 99 55 55 55
Z HL_E E-STAR LL Correction value for preheating TH_E set value under LL
environment
1 - 99 55 55 55
AA PRE-JOB LL Correction value for resetting from preheating
TH_UM+TH_E set value under LL environment
1 - 99 55 55 55
AB HL_LM E-STAR LL Correction value for preheating TH_LM set value under LL
environment
1 - 99 55 55 55
AC HL UM HEAVY2 CL LL Correction value for heavy paper 2 TH_UM set value under
LL environment
1 - 99 55 55 55
AD HL LM HEAVY2 CL LL Correction value for heavy paper 2 TH_LM set value under
LL environment
1 - 99 55 55 55
AE HL E HEAVY2 CL LL Correction value for heavy paper 2 TH_E set value under
LL environment
1 - 99 50 50 50
AF HL_UM WARMUP_120L LL Correction value for TH_UM set value in WarmUp at 120°C
or below under LL environment
1 - 99 55 55 55
AG HL_LM WARMUP_120L LL Correction value for TH_LM set value in WarmUp at 120°C
or below under LL environment
1 - 99 55 55 55
AH HL_E WARMUP_120L LL Correction value for TH_E set value in WarmUp at 120°C
or below under LL environment
1 - 99 50 50 50
AI LO_WARMUP_TIME_LL Correction value for AF-AH applying time (timer from
Ready complete) under LL environment
1 - 99 50 50 50
AJ HL_UM WARMUP_120H LL Correction value for TH_UM set value in WarmUp at 120°C
or above under LL environment
1 - 99 55 55 55
AK HL_LM WARMUP_120H LL Correction value for TH_LM set value in WarmUp at 120°C
or above under LL environment
1 - 99 55 55 55
AL HL_E WARMUP_120H LL Correction value for TH_E set value in WarmUp at 120°C
or above under LL environment
1 - 99 50 50 50
AM HI_WU_TIME_LL Correction value for AJ-AL applying time (timer from Ready
complete) under LL environment
1 - 99 50 50 50
AN HI_WU_FM_ON_TMP_LL Correction value for FM prior rotation start TH_UM in
WarmUp at alpha °C or above under LL environment
1 - 99 45 45 45
AO HI_WU_END_TIME_LL Correction value for WarmUp completion time in WarmUp
at alpha °
C or above under LL environment
1 - 99 50 50 50
AP HI_WU_JOB_SET_TMP_LL Correction value for Job Enable TH_UM temperature in at
alpha °C or above under LL environment
1 - 99 55 55 55
AQ HI_WARMUP_BORDER_LL Correction value for the threshold value alpha applying
SIM43-1-AN - AP under LL environment
1 - 99 50 50 50
AR LO_WU_JOB_SET_TMP_LL Correction value for Job Enable TH_UM temperature in at
alpha °C or below under LL environment
1 - 99 55 55 55
AS ROT_TIME_AFTER_JOB_LL Correction value for the after rotation time when completing
a job under LL environment
1 - 99 50 50 50
Item/Display Content
Setting
range
Default value Destination
linkage