MX-5001N MAINTENANCE 8 – 48
3. Maintenance and disassembly
A. Maintenance timing display
The message of maintenance execution timing is displayed when
each counter reaches the set value. The relationship between the
messages and the counters is shown blow.
(1) (Maintenance timing) (Frameless)
a. Maintenance counter
After completion of the maintenance, execute SIM 24-4 (Mainte-
nance counters (total, color) clear).
b. Transfer unit system counters
After completion of the maintenance, execute SIM 24-4 (Primary
and secondary transfer unit counters (number of the transfer unit
print counter, accumulated traveling distance of the transfer unit,
days of use of the transfer unit) clear).
c. Fusing unit counter
After completion of the maintenance, execute SIM 24-4 (Fusing
unit counters (number of the fusing unit print counter, days of use
of the fusing unit) clear).
d. Drum cartridge system counters
After completion of the maintenance, execute SIM 24-7 (Drum
counters (number of the drum print counter, accumulated travel-
ing distance of the drum) clear).
e. Developer cartridge system counters
After completion of the maintenance, execute SIM 24-5 (Devel-
oper counters (number of the developer print counter, accumu-
lated traveling distance of the developer) clear).
(2) [Maintenance timing] (Framed)
a. Maintenance counter
After completion of the maintenance, execute SIM 24-4 (Mainte-
nance counters (total, color) clear).
(3) [Check the waste toner box.] (Framed)
After detection of the waste toner full, reset the full detection by
opening/close of the front door.
Code Content
Print job
Enable/
Disable
TA When the maintenance counter (total) reaches 90% of
the set value of SIM21-1 (When the setting of SIM26-
38 is “print stop”).
When the maintenance counter (total) reaches the set
value of SIM21-1 (When the setting of SIM26-38 is
“print allowing”).
Enable
CA When The maintenance counters (color) reaches
90% of the set value of SIM21-1 (When the setting of
SIM26-38 is “print stop”).
When The maintenance counters (color) reaches the
set value of SIM21-1 (When the setting of SIM26-38 is
“print allowing”).
Enable
AA WhenThe maintenance counters (both of total and
color) reaches 90% of the set value of SIM21-1
(When the setting of SIM26-38 is “print stop”).
When The maintenance counters (both of total and
color) reaches the set value of SIM21-1 (When the
setting of SIM26-38 is “print allowing”).
Enable
Code Content
Print job
Enable/
Disable
TK1 The primary transfer unit life end reaches 300,000
sheets.
Enable
TK2 The secondary transfer unit life end reaches 300,000
sheets.
Enable
Code Content
Print job
Enable/
Disable
FK1 The fusing upper heat roller life end reaches 200,000
sheets.
Enable
FK2 The fusing lower/external heat roller life end reaches
300,000 sheets.
Enable
FK3 The fusing web life end reaches 150,000 sheets. Enable
Code Content
Print job
Enable/
Disable
DK The drum cartridge life end (K) reaches 150,000
sheets, or the accumulated number of rotations of the
drum (K) reaches 840K.
Enable
DC The drum cartridge life end (C) reaches 100,000
sheets, or the accumulated number of rotations of the
drum (C) reaches 840K.
Enable
DM The drum cartridge life end (M) reaches 100,000
sheets, or the accumulated number of rotations of the
drum (M) reaches 840K.
Enable
DY The drum cartridge life end (Y) reaches 100,000
sheets, or the accumulated number of rotations of the
drum (Y) reaches 840K.
Enable
Code Content
Print job
Enable/
Disable
VK The developer life end (K) reaches 150,000 sheets, or
the accumulated number of rotations of the developer
(K) reaches 840K.
Enable
VC The developer life end (C) reaches 100,000 sheets, or
the accumulated number of rotations of the developer
(C) reaches 840K.
Enable
VM The developer life end (M) reaches 100,000 sheets,
or the accumulated number of rotations of the
developer (M) reaches 840K.
Enable
VY The developer life end (Y) reaches 100,000 sheets, or
the accumulated number of rotations of the developer
(Y) reaches 840K.
Enable
Code Content
Print job
Enable/
Disable
TA The maintenance counters (total) reaches the set
value of SIM21-1, and SIM26-38 is set to Print
Disable.
Disable
CA The maintenance counters (color) reaches the set
value of SIM21-1, and SIM26-38 is set to Print
Disable.
Disable
AA The maintenance counters (both of total and color)
reaches the set value of SIM21-1, and SIM26-38 is
set to Print Disable.
Disable
Code Content
Print job
Enable/
Disable
- Waste toner full Disable