MX-5001N SIMULATION 6 – 104
50-22
Purpose
Adjustment
Function (Purpose)
Used to adjust the image registration. (Main
scan direction, sub scan direction) (Auto
adjustment)/OPC drum phase adjustment
(Auto adjustment)
Section
Operation/Procedure
1) Select a target adjustment item with [REGIST] or [DRUM POS]
or [ALL] key.
2) Press [EXECUTE] key.
The adjustment is automatically performed, and the adjust-
ment data are displayed.
NOTE: The contents of the following list are mainly used by the
technical division, and are not necessary for the market.
*1: The color image skew adjustment is performed according to this display value.
When "R" is displayed in front of the value, turn and click the skew adjustment screw (LSU) clockwise by the value.
When "L" is displayed in front of the value, turn and click the skew adjustment screw (LSU) counterclockwise by the value.
At that time, the values under the decimal point are rounded.
ALL The image resist adjustment (in the main scanning
direction and the sub scanning direction) and the OPC
drum phase adjustment are automatically performed.
REGIST The image resist adjustment (in the main scanning
direction and the sub scanning direction) is automatically
performed.
DRUM POS The OPC drum phase adjustment (automatic adjustment)
is automatically performed.
Item/Display Content Display
Default
value
NOTE
ALL
Image
registration
adjustment/
OPC drum
phase
adjustment
REGIST
(Auto image
registration
adjustment)
MAIN F C Image registration adjustment value (Main scanning
direction) (Position of writing by cyan laser is F side)
1.0 -
199.0
100
M Image registration adjustment value (Main scanning
direction) (Position of writing by magenta laser is F side)
1.0 -
199.0
100
Y Image registration adjustment value (Main scanning
direction) (Position of writing by yellow laser is F side)
1.0 -
199.0
100
MAIN R C Image registration adjustment value (Main scanning
direction) (Position of writing by cyan laser is R side)
1.0 -
199.0
100
M Image registration adjustment value (Main scanning
direction) (Position of writing by magenta laser is R side)
1.0 -
199.0
100
Y Image registration adjustment value (Main scanning
direction) (Position of writing by yellow laser is R side)
1.0 -
199.0
100
SUB C Image registration adjustment value (Sub scanning
direction) (Cyan drum to black drum)
1.0 -
199.0
100
M Image registration adjustment value (Sub scanning
direction) (Magenta drum to cyan drum)
1.0 -
199.0
100
Y Image registration adjustment value (Sub scanning
direction) (Yellow drum to magenta drum)
1.0 -
199.0
100
SKEW C Calculated result of print skew amount (Cyan) -99.9 -
99.9
- If the value is plus, R is
displayed to left side of
numerical value. If the
value is minus, L is
displayed to left side of
numerical value.
When the value is -4 -
+4, "(OK)" is place at
the back of the value.
For the other cases,
"(NG)" is displayed. *1
M Calculated result of print skew amount (magenta) -99.9 -
99.9
-
Y Calculated result of print skew amount (yellow) -99.9 -
99.9
-
DRUM POS
(Auto OPC
drum phase
adjustment)
PHASE Phase
adjustment
value BK
CL
Angle step
0°(1) 45°(2) 90°(3) 135°(4) 180°(5) 225°(6)
270°(7) 315°
(8)
1 - 8 2 Same item as
SIM44-31.
Phase
adjustment
value C
2 Same item as
SIM44-31.
(50-sheet machine)
Phase
adjustment
value M
4
Phase
adjustment
value Y
5
1
: Oct. 24 2008