MX-5001N MAINTENANCE 8 – 25
(2) Web unit removal
1) Remove the screw and the step screw. Release the fusing
lever, and remove the fusing unit.
2) Disconnect the connector, remove two screws, and remove
the web unit.
Maintenance: Replace at every 150K.
* When installing, engage the harness with the rib.
(3) Web roller bearing removal
1) Remove the screw, and remove the web roller bearing.
Maintenance: Replace at every 150K.
(4) Pressure roller bearing/pressure roller removal
1) Remove the web spring, and remove the pressure roller bear-
ing.
Maintenance: Replace at every 150K.
2) Remove the pressure roller.
Maintenance: Replace at every 150K.
(5) Web roller/winding regulation gear removal
1) Remove the left and the right springs, and remove the web
operation shaft.
2
1
1
1
3