MX-5001N MAINTENANCE 8 – 46
16) Remove the connector from the DSPF CL inverter PWB.
17) Remove the screw, and remove the intersecting point plate.
Remove the lower door.
18) Remove the screw, and remove the intersecting point plate.
Remove the white reference plate.
19) Remove the screw, and remove the scanning section cover.
Remove the screw, and remove the lamp unit.
20) Remove the screw, and remove the DSPF copy lamp.
21) Clean the scanning glass (back surface).
Maintenance: Clean at every 150K.
22) Remove the screw, and remove the reflector.
Maintenance: Clean at every 150K.
23) Remove the screw, and remove the transport PG upper.