MX-M700N SIMULATION 7 – 70
66-36
Purpose
Operation test/Check
Function (Purpose)
Used to check interface between MFPC
controller and MDMC. (Check of the data
line or the command line)
Section
FAX
Operation/Procedure
1) Enter the number corresponding to the check mode with 10-
key.
2) Press [START] key.
When check is completed normally, "OK" is displayed. Incase of an
error, "NG" is displayed.
When check is "repeat," the operation is continued until the result is
NG or [SYSTEM SETTINGS] key is pressed.
66-39
Purpose
Setting
Function (Purpose)
Used to set the destination specifications.
Section
FAX
Operation/Procedure
1) Enter the number corresponding to the destination.
2) Press [START] key.
66-42
Purpose
Setting
Function (Purpose)
Reloads the PIC program installed to FAX
BOX.
Section
FAX
Operation/Procedure
NOTE: Before processing, permit writing to the FAX PROGRAMA.
(Cancel the write protection)
1) Press [1] key to carry out the writing. Press [2] key to cancel.
2) If the operation is normally completed, "OK" is displayed.
When the error occurs, "NG" is displayed.
(Cause of the ERROR)
* State is write-protection.
* PIC is not mounted.
* Access trouble to PIC
66-43
Purpose
Adjustment/Setup
Function (Purpose)
Setting of the PIC adjustment value
Section
FAX
Operation/Procedure
NOTE: Before processing, permit writing to the FAX PROGRAMA.
(Cancel the write protection)
1) Present setting is highlight-displayed on the side of item.
2) Use the numeric keys to enter the adjustment value. Press the
[P] key to memorizes the input value.
3) Press [1] to writing the adjustment value collectively to PIC that
installed to the FAX BOX.
* If the operation is normally completed, "WRITING OK" is dis-
played. When the error occurs, "NG" is displayed.
1MFPC ← MDMC Date line once only
2MFPC → MDMC Date line once only
3MFPC ← MDMC Data line repeat
4MFPC → MDMC Data line repeat
5MFPC ← MDMC Command line once only
6MFPC → MDMC Command line once only
7MFPC ← MDMC Command line repeat
8MFPC → MDMC Command line repeat
SIMULATION 66-36
MFPC-MDMC I/F CHECK. INPUT 1-8, AND PRESS START.
1. MFPC<-MDMC(DATA once)
2. MFPC->MDMC(DATA once)
3. MFPC<-MDMC(DATA repeat)
4. MFPC->MDMC(DATA repeat)
5. MFPC<-MDMC(CMD once)
6. MFPC->MDMC(CMD once)
7. MDPC<-MDMC(CMD repeat)
8. MFPC->MDMC(CMD repeat)
1
SIMULATION 66-39
FAX DESTINATION SETUP.
SELECT 1-6, AND PRESS START
0. NO DESTINATION
1. JAPAN
2. U.S.A./CANADA
3. EUROPE
4. AUSTRALIA
5. CHINA
6. ASIA&OTHERS
1
SIMULATION 66-42
PIC PROGRAM RELOAD
ARE YOU SURE?
1.YES
2.NO