EasyManua.ls Logo

Shearwater TERN - Page 17

Shearwater TERN
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
Page 17
Doc. 15301-RevB (2023-11-24)
m
min
GF
35/75
GF99
22
%
136
%
SurfGF
SURFACE
m
min
GF
35/75
GF99
22
%
15
TTS
SURFACE
m
min
GF
35/75
GF99
22
%
15
TTS
SURFACE
Gradient Factor
The deco conservatism value when
the deco model is set to GF� The low
and high gradient factors control
the conservatism of the Bühlmann
GF algorithm� See “Clearing up the
Confusion About Deep Stops” by
Erik Baker for more information�
GF99
The current gradient factor as a
percentage (i�e� super-saturation
percent gradient)
0% means the leading tissue super-saturation is equal
to ambient pressure� Displays “On Gas” when tissue
tension is less than the inspired inert gas pressure�
100% means the leading tissue super-saturation is
equal to the original M-Value limit in the Bühlmann
ZHL-16C model�
GF99 is displayed in Yellow when the current gradient
factor modified M-Value (GF High) is exceeded�
GF99 is displayed in Red when 100% (un-modified
M-Value) is exceeded�
Time-To-Surface (TTS)
The time-to-surface in minutes� This
is the current time to ascend to the
surface including the ascent plus
all required deco stops and safety
stops�
Temperature
The current temperature in degrees
Celsius or degrees Fahrenheit�
Temperature units can be set in the
Display settings menu�
Battery
The Tern’s remaining battery level
expressed as a percentage
Displays in yellow when battery is low and needs to
be recharged� Displays in red when battery is critically
low and must be recharged immediately
Pressure
The pressure in millibars� Two values are shown,
the surface (surf) pressure and the current (now)
pressure�
Note that typical pressure at sea level is 1013 millibar,
although it may vary with the weather (barometric
pressure)� For example, in a low pressure system
surface pressure may be as low as 980 millibar, or as
high as 1040 millibar in a high pressure system�
For this reason, the PPO2 displayed on the surface
may not exactly match the FO2 (fraction of O2),
although the displayed PPO2 is still correct�
The surface pressure is set based on the lowest
pressure the Tern sees in the 10 minutes prior to the
start of a dive� Therefore, altitude is automatically
accounted for and no special altitude setting is
required�
TEMP
21 49
BATTERY
%
C
m
min
SURFACE
TEMP
21 49
BATTERY
%
C
m
min
SURFACE
mBar SURF
1013
mBar NOW
4943
m
min
SURFACE

Table of Contents