0 - reports are disabled
1-120 (1-120s) - report interval
NOTE: This Parameter is in relation to Parameter No. 36.
NOTE: Setting the value to less than 30s can cause the Z-Wave network congestion state (slow
Device response and decreased network stability).
Parameter No. 91 - Water Alarm
This parameter determines which alarm frames the Device should respond to and how. The
parameters consist of 4 bytes, the three most significant bytes are set according to the official
Z-Wave protocol specification.
Values size: 4 Byte
Default value: 0
Values & descriptions:
0 no action
1 open relay
2 close relay
Parameter No. 92 - Smoke Alarm
This parameter determines which alarm frames the Device should respond to and how. The
parameters consist of 4 bytes, the three most significant bytes are set according to the official
Z-Wave protocol specification.
Values size: 4 Byte
Default value: 0
Values & descriptions:
0 no action
1 open relay
2 close relay
Parameter No. 93 - CO Alarm
This parameter determines which alarm frames the Device should respond to and how. The
parameters consist of 4 bytes, the three most significant bytes are set according to the official
Z-Wave protocol specification.