EN.
26
11. Z-Wave Notifications Command class
11.1 Overheat detected
Z-Wave
Notification
Type Name
Z-Wave
Notification
Name
LED
colour
status
Device
reaction
Action to restore
Device
specific
Z-Wave
definition
Heat Alarm
Overheat
detected
Check
the RGB
LED
signaliz
ation
table
Switch OFF
all outputs
and send
notification
Any of the
following activities
reset this alarm:
power cycle,
Remote Device
reboot (with
Parameter No.
117), short press
on the S button,
press on any
switch/push-
button connected
to any SW (SW,
SW1, SW2, …)
terminal.
YES
notification
type=heat
alarm
Value=0x04,
event=State
Notification
name=Overh
eat detected
Value=0x02,
Version=V2
11.2 Overcurrent detected O
Z-Wave
Notification
Type Name
Z-Wave
Notification
Name
LED colour
status
Device
reaction
Action to
restore
Device
specific
Z-Wave
definition
Power
Management
Overcurrent
detected O
(O1)
Check the
RGB LED
signalization
table
Switch OFF
the output
O (O1) and
send
notification
Any of the
following
activities reset
this alarm:
power cycle,
Remote Device
reboot (with
Parameter No.
YES
notification
type=power
management
Value=0x08.
event=State
Notification
name=Over-
current
detected