EN.
29
• BASIC_SET: set On / Off state at the associated device
Root device - Association Group 3
Association Group 3
Allowed nodes: 9
It is assigned to switch connected to the SW (SW1) terminal (uses Switch Multilevel command
class). Triggered by SW (SW1).
It is recommended to use push buttons for this association. Supports the following command
classes:
• SWITCH_MULTILEVEL_START_LEVEL_CHANGE: initiate a transition to a new level
(increase or decrease light intensity in case of dimmer, or move shutter up or down, …)
• SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE: stop an ongoing transition (stop increase
or decrease light intensity in case of dimmer, or stop moving shutter up or down, …)
13. Supported load types
• Resistive (incandescent bulbs, heating devices)
• Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-
conditioners)
• Capacitive (capacitor banks, electronic equipment, motor start capacitors)