EN.
7
or multimeter. When you are sure that there is no voltage, you can proceed to connecting the
wires. ⚠CAUTION! Use only one phase AC circuit. Do not use mixed AC and DC circuits.
⚠CAUTION! Do not allow children to play with the push-buttons/ switches connected to the
Device. Keep the devices for remote control of Shelly Qubino (mobile phones, tablets, PCs)
away from children.
⚠RECOMMENDATION: Place the antenna as far away as possible from metal elements as they
can cause signal interference.
⚠RECOMMENDATION: Connect the Device using solid single-core wires with increased
insulation heat resistance not less than PVC T105°C (221°F).
⚠RECOMMENDATION: For inductive appliances that cause voltage spikes during switching
on/off, such as electrical motors, fans, vacuum cleaners and similar ones, RC snubber (0.1 µF /
100 Ω / 1/2 W / 600 VAC) should be connected parallel to the appliance.
If you are using AC power supply connect the load to the O terminal of the Device and the
Neutral wire, as shown on Fig. 1. Connect the Live wire to an L terminal of the Device.
Connect the Neutral wire to a N terminal of the Device. Connect a switch or a push-button to
the Device SW terminal and any of the unused L terminals of the Device.
If you are using DC power supply, connect the wires as shown on Fig 2. Connect the load to the
O terminal of the Device and the DC+ wire. Connect the GND wire to a ⊥ terminal of the Device.
Connect the DC+ wire to a + terminal of the device. Connect the switch/push-button to the SW
and any of the unused ⊥ terminals of the Device.