or multimeter. When you are sure that there is no voltage, you can proceed to connecting the
wires. CAUTION! Use only one phase AC circuit. Do not use mixed AC and DC circuits.
CAUTION! Do not allow children to play with the push-buttons/ switches connected to the
Device. Keep the devices for remote control of Shelly Qubino (mobile phones, tablets, PCs)
away from children.
RECOMMENDATION: Place the antenna as far away as possible from metal elements as they
can cause signal interference.
RECOMMENDATION: Connect the Device using solid single-core wires with increased
insulation heat resistance not less than PVC T105°C (221°F).
RECOMMENDATION: For inductive appliances that cause voltage spikes during switching
on/off, such as electrical motors, fans, vacuum cleaners and similar ones, RC snubber (0.1 µF /
100 Ω / 1/2 W / 600 VAC) should be connected parallel to the appliance.
If you are using AC power supply connect the load to the O terminal of the Device and the
Neutral wire, as shown on Fig. 1. Connect the Live wire to an L terminal of the Device.
Connect the Neutral wire to a N terminal of the Device. Connect a switch or a push-button to
the Device SW terminal and any of the unused L terminals of the Device.
If you are using DC power supply, connect the wires as shown on Fig 2. Connect the load to the
O terminal of the Device and the DC+ wire. Connect the GND wire to a terminal of the Device.
Connect the DC+ wire to a + terminal of the device. Connect the switch/push-button to the SW
and any of the unused terminals of the Device.