A- Engine information:
The main values of the system appear:
Details:
Stepper Position: opening value of the air valve (stepper) -> 35 < 50 < 75. Too weak value: Leak Valve /
engine air intake for example.
Too high value: throttle body injection clogged for example.
Information : correct value of the air valve: motor at 80 °C after being operated for15 m and idle for2 m.
Throttle position: engine stopped value: 0% Maximum opening: 100%
If the value is not equal to 0% when the engine is off, it means that adaptation has not been made:
Reboot the system several times (Switch off ignition. Wait until the relay slap calculator makes a clacking sound.
Switch the motorcycle back on). The step equals 0.5%.
State Stop button: state of the emergency stop button. 0: disabled, 1: enabled.
Engine status: ES (engine ready to start), ST (engine starts), IS (idle regime), PL (acceleration), PU (decelera-
tion), PUC (cut injection deceleration).
Injection diagnostic tool SYNERJECT