52(61)
[F.98]. Enter correct password to enter [F.05], then press to switch to [F.12].
4.4.2 Modify a Parameter
Press to increase parameter value. Keep on pressing to quickly
increase it's value until the maximum of it. Press to reduce parameter value.
Keep on pressing to reduce it's value until the minimum of it. Press to
confirm parameter setting and store it's value into the micro-processor and to
enter next setting item. If you did not change anything, press to enter into
next setting item. Press to cancel parameter setting and return back to
current setting screen. If you did not change anything, press to enter into
next setting item.
4.4.3 Finish Parameter Setting
Keep on pressing for about 1 sec. to return to normal display mode. If you
did not touch any keys for 20 secretary, the machine will return to normal display
mode without storing any changes of the parameter.
4.4.4 Process Parameter List
Para.
code
Functions Value Note
F.05
Material conveying delayed time
The delayed time between first material conveying and later
conveying action.
0 stands for no delaying time.
Action code: S.06
0
seconds
9990
seconds
10
seconds
for unit
F.06
Filter screen cleaning time before material conveying
0 stands for no filter cleaning action.
Action code: S.01
3
seconds
0-99
seconds
-
F.07
Filter screen cleaning time after material conveying
0 stands for no filter cleaning action.
Action code: S.03
3
seconds
0-99
seconds
-
F.CT
Cycle of mesh cleaning
Mesh cleaning is done after several times' suction.
3
seconds
1~99
seconds
-
F.08
Check material discharging time
Check material discharging time after material conveying. If
there are directive signals, then the machine gets into next
procedure. If not, add 1 to material shortage counter. When
this situation continues until material shortage times exceed
the setting value of [F.09], the machine will raise the alarm.
Action code: S.04
10
seconds
0-99
seconds
-

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shini SAL-UGP Series and is the answer not in the manual?

Shini SAL-UGP Series Specifications

General IconGeneral
BrandShini
ModelSAL-UGP Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals