Code 39
•
2/5 interleaved
•
Code 128 family
You can activate further code types and set other decoder properties (Device Tree >
Parameters > Code Configuration).
Scanning frequency
You can set the scanning frequency in the range from 400 Hz to 1200 Hz (Device Tree
> Parameters > Reading Configuration).
Ethernet interface
Use the Ethernet page to make adaptations to the IP address and the subnet mask via
the “Ethernet” (Device tree > Parameter > Network /Interfaces/IOs > Ethernet).
Object trigger control
If the device needs to be operated with an additional connected read cycle sensor, for
example as a photoelectric sensor on switching input “Sensor 1”, select the setting
“Sensor 1” (Device Tree > Parameters > Object Trigger Control).
Test and, if necessary, modify the specified settings when operating the system under
real conditions.