12.5 Ambient data
CLV63x CLV64x CLV65x
Vibration resistance EN 60068-2-6: 2008-02
Shock resistance EN 60068-2-27: 2009-05
EMC test Radiated emission: Acc. to EN 61000-6-3 (2007-01), electromagnetic
immunity: Acc. to EN 61000-6-2 (2005-08)
Ambient operating
temperature
Device without heating:
0 °C ... +40 °C
Device with heating:
-35 °C ... +35 °C
Storage temperature -20 °C ... +70 °C
Permissible relative
humidity
0% ... 90%, non-condensing
12.6 Reading field diagrams
12.6.1 Reading field conditions
Test code Code 128
Print contrast >90%
Tilt ±45°
Ambient light <2000 lx
Good read rate >75%
NOTE
Min. and max. reading distances are measured radially from the device.
12 TECHNICAL DATA
64
O P E R A T I N G I N S T R U C T I O N S | CLV63x, CLV64x, CLV65x 8019588/2017-01-20 | SICK
Subject to change without notice