IDM corded 
 
 
© SICK AG · Germany · All rights reserved · Subject to change without notice 
 
3.12.2  Data Formatter  
The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers 
or terminals. It allows you to select desired barcode symbologies for formatter control and provides Multiple 
Position Insertion and Multiple Character Insertion (max three characters) in the identified position.  
 
 
 
       
Family Code Selection  P.C.  Parameter Selection  1
st
 Option Code  2
nd
 Option Code 
Formatter Control 
SS  Disable   FIN   
MS 
Select one barcode symbology  (2 digits) 
Automatic termination 
MS 
Select all barcode symbologies  00 
Automatic termination 
1st insertion 
SS  Disable   FIN   
DS 
Enable  Position: (2 digits)  [1-3 characters]; FIN 
 
 
Define position (refer 
to chapter 3.12.7) 
max. 3 characters can be 
inserted 
2nd insertion 
SS  Disable   FIN   
DS 
Enable  Position: (2 digits)  [1-3 characters]; FIN 
 
 
Define position (refer 
to chapter 3.12.7) 
max. 3 characters can be 
inserted 
3rd insertion 
SS  Disable   FIN   
DS 
Enable  Position: (2 digits)  [1-3 characters]; FIN 
 
 
Define position (refer 
to chapter 3.12.7) 
max. 3 characters can be 
inserted 
4th insertion 
SS  Disable   FIN   
DS 
Enable  Position: (2 digits)  [1-3 characters]; FIN 
 
 
Define position (refer 
to chapter 3.12.7) 
max. 3 characters can be 
inserted 
 
While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, 
Data Length, Prefix/Suffix Symbology ID or Record Suffix. All of the above programmable parameters perform 
the same function depending on your setting. 
Regarding the “Bar Code Selection” and “Position Calculation” of data formatter, please refer to page 110 
and 111 for details. All “Character” input should be referred to the ASCII/HEX Table listed in the Appendix 
(page 119) to find matched HEX value.