IDM corded 
 
 
© SICK AG · Germany · All rights reserved · Subject to change without notice 
 
ACK Indication 
Disable: There’s neither LED nor beeping indication for this setting. 
Enable: There’s a specific LED and beeping indication for this setting. 
 
3.5.4  Response Time-out, Baud Rate 
 
 
     
Family Code Selection  P.C.  Parameter Selection  Option Code 
Serial Response Time-out 
SS  None  0 
 
 
 
SS  200 mseconds  1 
SS  500 mseconds   2 
SS  800 mseconds  3 
SS  1 second  4 
SS  2 seconds  5 
SS  3 seconds  6 
SS  4 seconds  7 
SS  5 seconds  8 
SS  8 seconds  9 
SS  10 seconds  A 
SS  15 seconds  B 
Baud Rate (BPS) 
SS  38.4K BPS  0 
SS  19.2K BPS  1 
SS  9600 BPS   2 
SS  4800 BPS  3 
SS  2400 BPS  4 
SS  1200 BPS  5 
SS  57.6K BPS  8 
SS  115.2K BPS  9 
 
The Serial Response Time-out is a pre-defined delay time for the Hand-held scanner to wait for handshaking, 
acknowledgment or non-acknowledgment from the host computer