Supplement Scan Voting 
The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be 
decoded before it is transmitted. It is helpful when decoding a mix of UPC/EAN symbols with and without 
supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, 
UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. 
When you select a higher level, it may impact the reading speed on poorly-printed, low contrast or damaged 
barcode labels. 
 
 
 
     
PROGRAM      F_DEFAULT 
Family Code Selection  P.C.  Parameter Selection  Option Code 
EAN Supplement Control 
SS  Disable all specific prefix supplement digital output   0 
 
 
 
SS  Enable all specific prefix supplement digital output  1 
SS  Enable 491 Supplement Digit Output  2 
SS  Enable 978/979 Supplement Digit Output  3 
SS  Enable 977 Supplement Digit Output  4 
SS  Enable 378/379 Supplement Digit Output  5 
SS  Enable 414/419 Supplement Digit Output  6 
SS  Enable 434/439 Supplement Digit Output  7 
UPC/ EAN Security Level 
SS  Level 0  0 
SS  Level 1   1 
SS  Level 2  2 
  Only available for UPC-A & EAN-13    
 
EAN Supplement Control 
If you select EAN with only 2 or 5 or 2/5 supplement digits and enable 491 prefix supplement digit output, the 
scanner will transmit EAN with 2, or 5 or 2/5 supplement digits bar codes starting with 491 prefix. The EAN 
without supplement digit will not be transmitted. 
If you select EAN with only 2 or 5 or 2/5 supplement digits and enable the other except 491 prefix 
supplement digit output, the scanner will transmit EAN with 2, or 5, or 2/5 supplement digits bar codes 
starting with specific prefix. The EAN without supplement digit will be transmitted.