3.10.3  Bluetooth Batch Scanning 
 
 
     
Family Code Selection  P.C.  Parameter Selection  Option Code 
Batch Scanning Link 
Control 
SS  Radio disable  0 
SS  Radio enable   1 
Stored Data Transmission 
SS  Either on cradle or by scanning barcode  0 
SS  On cradle  1 
SS  Scan barcode   2 
Delete Stored Data after 
Transmission 
 
SS  Disable   0 
SS  Enable  1 
Field Delimiter 
 
SS  None  0 
SS  ,   1 
SS  SPACE  2 
SS 
3 
SS  .  4 
SS  User define  5, [00-7F] 
Batch Data Quantity 
Output Format 
SS  As many times as the quantity indicates   0 
SS  <Quantity><Field Delimiter><Scanned Data>  1 
SS  <Scanned Data><Field Delimiter><Quantity>  2 
Data Transmission Format 
 
SS  Disable (scanned data only)   0 
SS  Leading with MAC address (MAC address & 
scanned data) 
1 
SS  Leading with ID No. (Scanner ID & scanned data)  2 
  Only available for RS-232, USB HID and USB COM interface 
in PAIR & PICO mode. 
 
 
Batch Scanning Link Control 
It’s a predefined radio option to control the radio-on or radio-off status under batch scanning operation. 
Please note that if “Radio disable” is selected, the radio link will be disconnected once you enter batch 