EasyManuals Logo

SICK IDM260 Series User Manual

SICK IDM260 Series
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
Bluetooth Operation Control (IDM Bluetooth
series)
Operating Instructions
IDM corded & IDM Bluetooth
86
© SICK AG · Germany · All rights reserved · Subject to change without notice
8017159/2014-04-24
3.10.2 Sleep Time-out, Power Off Time-out
PROGRAM
F_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
Sleep Time-out of
connected state
SS 6 (x5) minutes FIN
MS 0-99 (x5) minutes (2 digits)
If you don’t want the scanner to enter sleep mode, please
set time-out to “0”.
Sleep Time-out of
disconnected state
SS 1 minute FIN
MS 0-99 minutes (2 digits)
If you don’t want the scanner to enter sleep mode, please
set time-out to “0”.
Power Off Time-Out
SS 6 (x5) minutes FIN
MS 0-12 minutes (2 digits)
If you don’t want the scanner to enter power off mode,
please set time-out to “0”.
Sleep Time-out control
The sleep time-out control can be set under radio connection or disconnection state. If the scanner is not
used within the preset time-out duration, it will automatically enter “Sleep Mode” for power saving purpose.
You can disable this function by setting the time-out duration to “0”.
Power off Time-out control
When the scanner is under sleep mode, it is preset to enter “Power Off” automatically if it is not woken up
after time-out duration. If you would like to wake up the scanner press the trigger button. Meanwhile you can
disable this function by setting the time-out duration to “0”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK IDM260 Series and is the answer not in the manual?

SICK IDM260 Series Specifications

General IconGeneral
BrandSICK
ModelIDM260 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals