Device 1
CDM420-0006
Load (e.g. PLC) 5
C
5
.
.
.
E
Result D
13
GND
5
Shield
+24 V* (V
S
)
V
S
GND
V
out
Result A
GND
B
1
2
1
For inductive load: 7
6
2
3
4
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
9 8
110
15
6
11
5
Figure 63: Wiring the “Result 1” and “Result 2” digital outputs of the device in the CDM420-0006 connection module.
Inductive load
NOTE
Provide an arc-suppression switch at the digital output if inductive load is present.
►
Attach a freewheeling diode directly to the load for this purpose.
Table 55: Assignment of placeholders to the digital outputs
Device CDM420-0006
Output A Pin B Pin C Signal D Terminal E
Result 1 13 12 Result 1 14
Result 2 14 13 Result 2 15
Characteristic data of the digital outputs
Table 56: Characteristic data of the “Result1” and “Result2” digital outputs
Type Switching
Switching behavior PNP switching to supply voltage V
S
Default settings in the device: no function, logic: not inverted (active
high)
Properties
•
Short-circuit protected and temperature protected
•
Not electrically isolated from the supply voltage V
S
Electrical values 0V ≤ V
out
1)
≤ V
S
(V
S
−1.5V) ≤V
out
≤V
S
at I
out
2)
≤100mA
1)
Output voltage.
2)
Output current.
NOTE
Assign the functions for the digital outputs in the device using a configuration tool, e.g.,
the configuration software SOPASET.
ANNEX 14
8027750//2022-12-15 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x
123