Procedure
– Install the SOPAS ET configuration software and the required device description
file on a computer
– Electrically connect the device to the computer
– Commission the device with the help of the “Quickstart” function in SOPAS ET. Use
the factory defaults as the basis for this.
– Perform a manual fine adjustment and configuration of the device to optimize the
functionality for the specific situation on site (reading and writing)
– Test the device for correct functioning in operational use.
7.3 SOPAS ET configuration software
The SOPAS ET configuration software is normally used to adapt the device to the read‐
ing situation on site. The optimized configuration data are then permanently saved to
the device using the “permanent” option. The data can also be stored on the computer
as a parameter set (project file) for archiving purposes.
The device can also permanently access the parameter set from an optional external
storage medium. This makes it easier to replace the device if necessary.
A device-specific microSD memory card, or the CMC600 parameter cloning module in
the Connection Device Basic or Connection Device Modular connection module are
available for this purpose. For more information, see "Information on initial commission‐
ing", page 70.
7.3.1 Functions of the SOPAS ET configuration software (overview)
NOTE
The manual for the SOPASET configuration software describes the general functions in
the program as well as the user interface.
•
Selecting the menu language
•
Setting up communication with the device
•
Password-protected configuration for different operating levels
•
...
The SOPAS ET configuration software provides the following functions, amongst others,
relating to the device:
•
Quickstart function with continuous read cycle triggering to demonstrate the trans‐
ponder recognition and data display
•
Access to the transponder content (reading and writing)
•
Management of device apps
•
Assistant for targeted configuration of the transponder read operation (Single Tag
ID Wizard)
•
Recording of device and communication data during operational use via the diag‐
nostics log file output
•
System diagnostics
7.3.2 Installing SOPAS ET and the device description file
NOTE
Depending on the situation on site, administrator rights may be required on the com‐
puter to install the software. The computer must provide a functioning Internet connec‐
tion.
COMMISSIONING 7
8027750//2022-12-15 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x
65
Subject to change without notice