12.2 Interfaces
RFU630-131xx
Table 24: Technical data for RFU630-131xx: Interfaces
RFU630-131xx
Ethernet
Protocols: TCP/IP, OPC UA (Companion Spec V1.0, from firm‐
ware V2.20)
Function: Host (data output of the read result)
Function: AUX for service
1)
Data transmission rate 10/100Mbit/s
Services: DHCP, NTP, HTTP/HTTPS
PROFINET
Protocol: PROFINET
Function: Host (data output of read result), PROFINET Single
Port
2)
Data transmission rate 10/100Mbit/s
PROFINET dual port via an external CDF600-22xx
3)
fieldbus
module
EtherNet/IP
Protocol: EtherNet/IP
Function: Host (data output of the read result)
Data transmission rate 10/100Mbit/s
EtherCAT®
Protocol: EtherCAT®
Function: Host (data output of the read result)
2)
Via external CDF600-0300
3)
fieldbus module (gateway mode)
to EtherCAT®
PROFIBUS
Protocol: PROFIBUS
Function: Host (data output of the read result)
2)
Via external CDF600-21xx fieldbus module
3)
to PROFIBUS
(RS-485)
Serial Host:
Protocol: RS-232, RS-422
Function: Host (data output of the read result)
Data transmission rate: 0.3kBd ... 115.2kBd
Cable: RS-232 (2-wire and ground)
Cable: RS-422 (4-wire and ground)
AUX:
Protocol: RS-232
Function: AUX for service
1)
Data transmission rate: 57.6kBd
Cable: RS-232 (2-wire and ground)
CAN
Protocol:
°
CSN (SICK CAN sensor network)
°
CANopen®
Function: Host (data output of the read result)
Data transmission rate: 20kBit/s ... 1MBit/s
Bus length: Depends on the data transmission rate and wire
cross-section
4)
USB 2.0
5)
Function: AUX for service
1)
TECHNICAL DATA 12
8027750//2022-12-15 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x
87
Subject to change without notice