RFU630-131xx
Digital inputs
•
Quantity: 2
•
Design: Physical, switching
•
Optional additionally: 2 inputs, version: logic, switching. Imple‐
mented using CMC600 module
3)
in the CDB
3)
or CDM con‐
nection module
3)
•
V
in
6)
= max. 30V, I
in
7)
= max. 5mA
•
Opto-decoupled, reverse polarity protected, adjustable
debounce time
Digital outputs
•
Quantity: 2
•
Design: Physical, switching
•
Optional additionally: 2 outputs, version: logic, switching.
Implemented using CMC600 module
3)
in the CDB
3)
or CDM
connection module
3)
•
V
out
8)
= V
S
9)
– 1.5V, I
out
10)
≤100mA (typical)
•
Short-circuit protected, temperature protected, not electrically
isolated from the supply voltage
Optical displays
•
7 RGB LEDs (status display) at top of front
•
1 RGB LED (process feedback) at center of front of antenna
cover. Display function can be set with pre-defined color
assignment
11)
Acoustic indicator
•
Beeper (buzzer), can be deactivated
•
Function for event signaling and volume adjustable
11)
Control elements
•
2 pushbuttons
•
Function: Selecting and starting or stopping functions
Configuration SOPAS ET configuration software, CoLa commands (telegrams),
web server, fieldbus controller (PLC) with additional support by
SICK function blocks
Programming Application-specific programming with the SICK AppStudio
12)
development environment.
You can find further information on the Internet at:
www.sick.com/SICK_AppStudio
1)
Service: e.g., configuration, diagnostics, transponder access or displaying the read result.
2)
Function blocks for PLC types from different manufacturers are available.
3)
Optional accessories.
4)
Typically: 250m at 250kBit/s and wire cross-section ≥0.34 mm
2
.
5)
The USB interface is only for temporary use as a service interface.
6)
Input voltage.
7)
Input current.
8)
Output voltage.
9)
Supply voltage.
10)
Output current.
11)
For example using the SOPAS ET configuration software.
12)
This functionality can be unlocked with the SDK6U SD card. Available online at: www.sick.com.
RFU630-041xx
Table 25: Technical data for RFU630-041xx: Interfaces
RFU630-041xx
Ethernet
•
Protocols: TCP/IP, OPC UA (Companion Spec V1.0, from firm‐
ware V2.20)
•
Function: Host (data output of the read result)
•
Function: AUX for service
1)
•
Data transmission rate 10/100Mbit/s
•
Services: DHCP, NTP, HTTP/HTTPS
12 TECHNICAL DATA
88
O P E R A T I N G I N S T R U C T I O N S | RFU63x 8027750//2022-12-15 | SICK
Subject to change without notice