RFU630-041xx
Optical displays
7 RGB LEDs (status display) at top of front
1 RGB LED (process feedback) at center of front. Display func‐
tion can be set with pre-defined color assignment
11)
Acoustic indicator
Beeper (buzzer), can be deactivated
Function for event signaling and volume adjustable
11)
Control elements
2 pushbuttons
Function: Selecting and starting or stopping functions
Configuration SOPAS ET configuration software, CoLa commands (telegrams),
web server, fieldbus controller (PLC) with additional support by
SICK function blocks
Programming Application-specific programming with the SICK AppStudio
12)
development environment.
You can find further information on the Internet at:
www.sick.com/SICK_AppStudio
1)
Service: For example configuration, diagnosis, transponder access or display of the read result.
2)
Function blocks for PLC types from different manufacturers are available.
3)
Optional accessories.
4)
Typically: 250m at 250kBit/s and wire cross-section ≥0.34 mm
2
.
5)
The USB interface is only for temporary use as a service interface.
6)
Input voltage.
7)
Input current.
8)
Output voltage.
9)
Supply voltage.
10)
Output current.
11)
For example using the SOPAS ET configuration software.
12)
This functionality can be unlocked with the SDK6U SD card. Available online at: www.sick.com.
NOTE
You will find SICK function blocks for various types of PLC from different manufacturers
on the product page.
The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N}
{P/N} corresponds to the part number of the product, see type label.
{S/N} corresponds to the serial number of the product, see type label (if indicated).
12.3 Mechanics and electronics
RFU630-131xx
Table 26: Technical data for RFU630-131xx: Mechanics and electrics
RFU630-131xx
Connection type Ethernet, serial
Power/serial data/CAN/I/O: 1 male connector, M12, 17-pin,
A-coded
Ethernet: 1 female connector, M12, 4-pin, D-coded
USB
1)
: 1 female connector, 5-pin, Micro-B type
External antennas: 3 female connectors, TNC reverse, mono-
static, 50Ohm impedance
Card slot for the MicroSD memory card
Supply voltage V
S
ES1 according to EN 62368-1, NEC protection class 2
(UL1310)
18V ... 30VDC
2)
3)
12V ... 30VDC
4)
optional
12 TECHNICAL DATA
90
O P E R A T I N G I N S T R U C T I O N S | RFU63x 8027750//2022-12-15 | SICK