7.4.4 Completing the configuration
Permanently save the entire configuration once it has been successfully tested:
°
Parameter set in the device: Click the button .
°
Configuration file on the computer: Click the buttons Device > Export SDV file.
7.5 Information on initial commissioning
The SOPAS ET configuration software on the computer is used to adapt the device to
the particular application on site. The default factory settings of the device are the
starting point for this. The default settings can also be accessed again after parameter‐
ization has been completed.
The parameter values (configuration data) in the working memory of the device can
be modified to optimize the functionality of the device. This is done by creating an
application-specific, further modifiable parameter set using SOPAS ET. The parameter
set with the current configuration data is then loaded into the permanent parameter
memory of the device.
NOTE
Recommendation: As part of a data backup plan, also save the current parameter set
outside the device memory. This makes it easier, if necessary (device failure, etc.), to
restore, to a replacement device of the same type, the current parameter set used to
date.
Memory organization for parameter set
Parameter set in the
main memory of the
device 8
Permanently saved
parameter set of the
device 5
Factory default setting of
the device 9
Device 2Optional: 1 Computer with SOPAS ET
Configuration Software 3
MicroSD memory card 4
Parameter memory module
CMC600 7
Volatile memory â
Opened project file
with current parameter
set of the device ß
Volatile memory â
Non-volatile memory á
Non-volatile memory á
Saved project file (*.sopas)
with archived parameter
set of the device à
Data base on hard drive
(non-volatile memory) ã
‒ and/or ‒ 6
Permanently saved
parameter set of the
device 5
Non-volatile memory á
Permanently saved
parameter set of the
device 5
Non-volatile memory á
Figure 36: Saving the parameter set and configuration using SOPAS ET
1
Optional
2
Device
3
Computer with SOPAS ET configuration software
4
MicroSD memory card
5
Permanently saved device parameter set
6
and/or
7
CMC600 parameter cloning module
8
Parameter set in the working memory of the device
9
Factory-set defaults for the device
ß
Opened project file with current device parameter set
à
Saved project file (*.sopas) with archived device parameter set
á
Nonvolatile memory
â
Volatile memory
ã
Data base on the hard drive (non-volatile memory)
7 COMMISSIONING
70
O P E R A T I N G I N S T R U C T I O N S | RFU63x 8027750//2022-12-15 | SICK
Subject to change without notice