For the characteristic data of the two external digital inputs, see the respective connec‐
tion diagrams for the connection modules in these operating instructions.
Wiring the digital inputs of the device via a connection module:
Connection mod‐
ule
Digital inputs Reference
CDB650-204 “SENS/IN 1”
“SENS/IN 2”
see "Wiring digital inputs of
the device in the CDB650-204",
page 106
External input 1 (“EXT. IN 1”)
External input 2 (“EXT. IN 2")
see "Wiring the external digital inputs
of the device in the CDB650-204",
page 108
CMD420-0006 “Sensor 1”
“Sensor 2”
see "Wiring digital inputs of the
device in the CDM420-0006",
page 119
External input 1 (“AUX In 1”)
External input 2 (“AUX In 2”)
see "Wiring the external digital inputs
of the device in the CDM420-0006",
page 120
If the digital inputs are wired via a connection module, observe the respective operating
instructions of the module used.
6.10 Wiring digital outputs
Physical digital outputs on the device
The two physical digital outputs “Result 1” and “Result 2” signal events in the read
operation. Different functions can be assigned to the outputs independently of each
other for this purpose. If the assigned event occurs, then the corresponding digital out‐
put switches after the end of the read cycle for the selected pulse duration, for example
(default).
The full complement of digital outputs is available in each case:
•
At the male connector of the device (M12, 17-pin, A-coded)
•
At the adapter cable with female connector, M12, 17-pin, A-coded and male
connector, D-Sub-HD, 15-pin
•
At the open end of the adapter cable with female connector, M12, 17-pin, A-coded
V
out
3
4
Digital output of device 1
!
"
Signal 2
GND
Figure 28: Wiring a digital output
1
Digital output of the device (“Result 1” or “Result 2”)
2
Output signal
3
Output voltage V
out
4
With inductive load: see note
!... "
For pin assignment, see respective device
ELECTRICAL INSTALLATION 6
8027750//2022-12-15 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x
57
Subject to change without notice