For CDM420-0006: Adapter cable with female connector, M12, 17-pin, A-coded and male
connector, D-Sub-HD, 15-pin
â
Cable with two male connectors, TNC reverse
NOTE
As an option, two additional external digital inputs and outputs are available for the
device. Parameter cloning module CMC600, installed in the Connection Device Basic or
Connection Device Modular connection module, is required for this purpose.
The modules can be delivered as optional accessories.
For details of the characteristics of the external digital inputs and outputs, see "Wiring
digital inputs ", page 55 and see "Wiring digital outputs ", page 57.
6.3.3 Use of the data interfaces
RFU630/RFU650
AUX 1
RS-232
CAN
Computer:
SOPAS ET
Configuration
software
7
HOST:
Further data
processing
8
Host 1
Computer/
HOST
RS-232 1
RS-422 1
◂ Configuration, ... 3
AUX 3
USB
◂ Configuration 4
◂ Data output 2
Ethernet
AUX 2 ◂ Configuration, ... 5
Host 2
◂ Data output 6
Figure 20: RFU630: Data interfaces and their preferred use
1
One of the two interface options can be selected
2
Read operation: Data output of the read result (configurable output format 1 or 2)
3
Service operation: Configuration with SOPAS ET, prepared representation of the read
result, transponder access, reading diagnostics or monitoring of the serial host interface
4
Service operation: Configuration with SOPAS ET. The USB interface must only be used
temporarily as a servicing interface.
5
Service operation: Configuration with SOPAS ET, processed read result display, trans‐
ponder access or reading diagnostics
6
Read operation: Data output of the read result (configurable output format 1 or 2),
recommended for high data volume
7
SOPAS ET configuration software
8
Data further processing
Table 6: RFU630: Functions relating to data interfaces
Interface option Host 1 AUX 1 Host 2 AUX 2 AUX 3
Assignable function
Serial
RS-232 or
RS-422
Serial
RS-232
Ethernet Ethernet USB
1)
Read result output (configurable
format 1 or 2)
O O O O
Read result output (customer out‐
put format)
O
Read diagnostics (fixed output for‐
mat)
O O O
2)
ELECTRICAL INSTALLATION 6
8027750//2022-12-15 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x
45
Subject to change without notice