RFU63x-041xx:
Bring one or more standards-compliant UHF transponders into the working range
of the external antenna(s).
2. Click the Start button on the Quickstart tab of SOPAS ET. SOPAS ET continuously
generates an automatic read cycle and lists the identified transponders one after
another in the Quickstart window.
Figure 32: SOPAS ET display of the detected transponders in the Quickstart window
Feedback about transponder detection in the UHF field
In Quickstart mode, the default lighting behavior of the process feedback LEDs indi‐
cates whether a UHF field is present and whether the device has detected transpond‐
ers.
The process feedback LED is in the center of the device front plate, and in this case,
lights up blue.
Table 16: Process feedback LED
LED status Status
At half brightness:
Permanently on UHF field available, no transponder in the field
At full brightness:
Flashing slowly (f = 1.25Hz) 1transponder in field
Flashing quickly (f = 2.5Hz) 2 transponders in the field
Flashing faster (f = 5Hz) More than 2transponders in field
COMMISSIONING 7
8027750//2022-12-15 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x