Operating mode: Read mode
Table 19: Function of the “process feedback” status indicator in read mode
Color Behavior Status
Blue Lights up for the dura‐
tion of the in-progress
reading interval
Read operation was started by an external or internal
trigger source, device has started an internal reading
interval (event)
Green Lights up briefly Device has ended the internal reading interval. Trans‐
ponder detected and optionally selected condition(s)
met -> Good Read (event)
Red Lights up briefly Device has ended the internal reading interval. Trans‐
ponder not detected or optionally selected condition(s)
not met -> No Read (event)
8.1.3 Operating options and configuration tools
NOTE
In addition to the existing operating instructions, the use of the RFU parameter
description is recommended:
•
This parameter description explains the UHF-RFID-specific parameters of all
device variants of the RFU6xx product family up to and including the “Service”
user level.
•
The parameter description assists with setting up applications using the SOPAS ET
configuration software.
The parameter description is available in English (part no. 8023085) and German (part
no. 8023084) as well as other languages if required.
NOTE
The parameter description can be found on the product page.
The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N}
{P/N} corresponds to the part number of the product, see type label.
{S/N} corresponds to the serial number of the product, see type label (if indicated).
The device can be operated and configured in the following 5 ways for specific tasks:
1. SOPAS ET configuration software
■
Standard configuration tool for the device
■
The configuration software and appropriate device description file are installed on
a computer. These are available online at: www.sick.com/SOPAS_ET
■
Password-protected configuration at four different operating levels (user levels):
Level User levels Note
1 Operator No entry of password required, no configura‐
tion possible
2 Maintenance personnel Entry of password required
3 Authorized client
4 Service
NOTE
The two user levels “Run” and “Maintenance” are only password protected if the
“Parameterization is password-protected” parameter in SOPAS ET is activated.
8 OPERATION
76
O P E R A T I N G I N S T R U C T I O N S | RFU63x 8027750//2022-12-15 | SICK
Subject to change without notice