2.1.1 Operational restrictions
The region assignment of the device is configured for the specific type when delivered
and cannot be changed. This enables the device to be operated in the approved region
without interfering with national protected frequencies (e.g., mobile communications).
Operating the same device in another region for which there is no approval is prohib‐
ited.
A region consists either of a group of countries or one country.
NOTE
The device approval was granted for a specific region. The region assignment cannot be
changed.
Use the device only in the region and country for which the device is approved.
Observe country-specific operating conditions for the device, see Technical Infor‐
mation RFU63x Regulatory Compliance Information.
When reselling the device, inform the buyer of the fixed region assignment.
When passing the device on to third parties, also include the Safety Notes, the
Technical Information RFU63x Regulatory Compliance Information and the RFU63x
operating instructions.
A printed copy of the Safety Notes and the Technical Information Regulatory Com‐
pliance Information are enclosed with the device.
NOTE
You will find the Technical Information RFU63x Regulatory Compliance Information, the
RFU63x operating instructions as well as the declarations of conformity and certificates
on the product page.
The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N}
{P/N} corresponds to the part number of the product, see type label.
{S/N} corresponds to the serial number of the product, see type label (if indicated).
2.1.2 Regulatory notes
See Technical Information RFU63x Regulatory Compliance Information (part no.
8026892).
2.1.3 Conditions for specified enclosure rating
To ensure compliance with the specified IP67 enclosure rating of the device during
operation, the following requirements must be met: If these requirements are not met,
the device does not fulfill any specified enclosure rating.
The shared side cover of the USB interface and card slot must be screwed tight
to the device. Recommended tightening torque for the cover screws: 40Ncm
±5Ncm.
The heads of the connecting cables plugged into the M12 electrical connections
must be screwed tight.
Any unused electrical M12 connections must be fitted with protective elements,
e.g., protective caps (as delivered). The protective elements are hand-tightened.
Any unused electrical connections for external antennas (TNC reverse) must be
fitted with screw-on metal protective elements (as delivered). The protective ele‐
ments are hand-tightened.
The same also applies to the EMC requirement (ESD) according to CE.
Positions of the individual elements see "Device view", page 16
SAFETY INFORMATION 2
8027750//2022-12-15 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x
9
Subject to change without notice