EasyManua.ls Logo

SIEB & MEYER SD2S 0362249xy - Page 103

Default Icon
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating mode
Drive function SERVO / VECTOR VF
Operating modes Speed Mode
Current reference value
Profile Velocity Mode
Interpolated position control
Electronic gear
Speed Mode
Software Connection
Drive function SERVO / VECTOR VF
Parameterization in soft‐
ware
drivemaster2
USB connection
RS232 connection
SERVOLINK 4 (only optical fibers)
Communication channels
Drive function SERVO / VECTOR VF
Control channel Digital inputs
Serial interface / RS485 / USB
SERVOLINK 4
CAN bus
DNC 8 Byte Telegram
Setpoint channel
Analog inputs
Serial interface / RS485 / USB
Internal setpoints
Encoder 0
(only with software package L04001 /
F04006)
SERVOLINK 4
CAN bus
DNC 8 Byte Telegram
Analog inputs
Serial interface / RS485 / USB
Internal setpoints
SERVOLINK 4
CAN bus
DNC 8 Byte Telegram
Control
Drive function
SERVO / VECTOR VF
Operating frequency 8 / 16 kHz 8 / 16 kHz
All-digital current control 16 kHz 8 / 16 kHz
All-digital speed control 16 kHz (62.5 µs) -
All-digital position control
4 kHz (250 µs)
(1)
-
(1)
Only with interpolated position control and electronic gear.
Interfaces
Drive function
SERVO / VECTOR VF
Digital inputs 9 inputs 24 V incl. 1 input (latch function 250 kHz (4 µs) sampling)
12 – 24 V high / 0 – 5 V low
Sampling 4 kHz (250 µs)
Function to be configured via software
Digital outputs
5 outputs 24 V (max. 100 mA per output)
Sampling 4 kHz (250 µs)
Function to be configured via software
Analog inputs
2 differential signal inputs
Operating range ±10 V
Maximum range ±12 V
Resolution internal 14 Bit
Sampling 4 kHz (250 µs)
Function to be configured via software
Analog outputs
2 outputs
Operating range 0 – 10 V
W
Appendix
Drive System SD2S - Hardware Description 0362X49xy / 0362129xy 103