3.6.9.6
Technical data 3TK2834
3TK2834-.A...
3TK2834-.B...
EMC emitted interference
EN 60947-5-1
Item designation
according to DIN 40719 extendable after IEC 204-2
according to IEC 750
KT
according to DIN EN 61346-2
F
Number of sensor inputs 1-channel or 2-channel
Design of the cascading
none
Type of the safety-related wiring of the inputs
two-channel
Product feature transverse contact-secure
Yes
Safety Integrity Level (SIL) according to IEC 61508
SIL3
SIL claim limit (for a subsystem) according to EN 62061
3
Safety integrity level (SIL)
for delayed release circuit
according to IEC 61508
Performance Level (PL)
according to ISO 13849-1
e
for delayed release circuit according to ISO 13849-1
Category
according to EN 954-1
4
according to ISO 13849-1
4
Safety device type according to IEC 61508-2
Type A
Probability of dangerous failure per hour (PFHD)
with high
demand rate according to EN 62061
1/h 0.0000000014
T1 value
for proof test interval or service life
according
to IEC 61508
a 20
Number of outputs
as contact-affected switching element
as NO contact safety-related
as NC contact for reporting function instantaneous
switching
0
as NO contact safety-related instantaneous switching
4
as NO contact safety-related delayed switching
0
Stop category according to DIN EN 60204-1
0
Design of the input
cascading-input/functional switching
No
feedback input
Yes
start input
No

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens 3TK28 and is the answer not in the manual?

Siemens 3TK28 Specifications

General IconGeneral
TypeSafety relay
Mounting TypeDIN rail mounting
Type of VoltageAC/DC
Control Supply Voltage at DC24 V
Performance Level According to EN ISO 13849-1PL e
Category According to EN ISO 13849-1Category 4
Mechanical Durability10, 000, 000 cycles
Electrical Durability100, 000 cycles
Protection ClassIP20
Product FunctionSafety Monitoring
Suitability for UseEmergency stop, safety doors
Supply Voltage Frequency50/60 Hz
Control Supply Voltage at AC at 50 Hz24 V
Control Supply Voltage at AC at 60 Hz24 V
Stop Category0
SIL According to IEC 61508SILCL 3
Type of Electrical ConnectionScrew Connection
Rated Control Supply Voltage24 V