Description of the individual safety relays
3.7 3TK28 safety relays with solid-state enabling circuits
3TK28 safety relays
114 Manual, 07/2016, NEB926157502000/RS-AB/003
EN 60947-5-1, EN 61000-6-2, EN 61000-6-4
• according to DIN 40719 extendable after
IEC 204-2 according to IEC 750
KT
• according to DIN EN 61346-2
F
Number of sensor inputs 1-channel or 2-channel
Type of the safety-related wiring of the inputs
single-channel and two-channel
Product feature transverse contact-secure
Safety Integrity Level (SIL) according to IEC 61508
SIL claim limit (for a subsystem)
2
Safety integrity level (SIL)
for delayed release circuit
—
• according to ISO 13849-1
d
• for delayed release circuit according to ISO
13849-1
—
• according to EN 954-1
3
• according to ISO 13849-1
3
Safety device type according to IEC 61508-2
Probability of dangerous failure per hour (PFHD)
with high demand rate according to EN 62061
1/h 0.000000011
for proof test interval or service life
a 20
as contact-less semiconductor
switching element
• for reporting function
– non-delayed
0
– delayed switching
0
• safety-related
– non-delayed
2
– delayed switching
0
Stop category according to DIN EN 60204-1