Mounting
4.3 Mounting the device on a level surface
3TK28 safety relays
Manual, 07/2016, NEB926157502000/RS-AB/003
185
Mounting the device on a level surface
Requirements
Please note the following requirements for mounting on a level surface:
● Please observe the information about the mounting position in the chapter "General
technical data (Page 18)".
● Two properly executed drill holes with thread or plug on the level surface
For details of the distances between the drilled holes, please refer to the relevant
dimension drawings in the chapter "Dimension drawings 3TK28 (Page 195)".
● Two screws with a maximum thread diameter of 4.8 mm
● Two plastic securing brackets
Please refer to the accessories list for the relevant article number in the chapter
"Accessories (Page 205)".
The procedure is shown applied to the 45 mm housing. The procedure for 22.5 mm
devices is analogous.
Procedure for mounting on a level surface
1 Insert the securing brackets into the openings
provided on the device until they engage.
2 Hold the device up to the surface prepared for
3 Insert the screws through the oblong holes in the
4 Screw the device onto the level surface so that it
is secure.