EasyManua.ls Logo

Siemens 3TK28 - Display of the Operating State

Siemens 3TK28
206 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the individual safety relays
3.7 3TK28 safety relays with solid-state enabling circuits
3TK28 safety relays
Manual, 07/2016, NEB926157502000/RS-AB/003
129
3.7.3.5
Display of the operating state
The operating state and functioning of the device are indicated by three LEDs:
POWER
RUN
FAULT
Operating states of 3TK2842
= off
= on
= flashing
LED
Operation
POWER RUN FAULT Line supply EMERGENCY
STOP
ON Outputs
On Not pressed Pressed On
Pressed
1)
Not pressed
Off
Not pressed
Not pressed
Off
3)
Pressed
Not pressed
On / Off
Self-test on startup approx. 7 s
Fault
Fault in electronics
Change of pin assignment during operation
Short-circuit to 24 V
2)
Off
Supply voltage missing
1)
Sensor circuits open; cross-circuit between sensors; short-circuit of sensors to ground.
2)
Only on circuit variant with "cross-circuit detection"
3)
Delay time running